{"product_id":"audel-installation-requirements-of-the-2002-national-electrical-code-isbn-9780764542787","title":"Audel Installation Requirements of the 2002 National Electrical Code","description":"A practical guide to the 2002 NEC\u003cbr\u003e \u003cbr\u003e As an electrician, your interest in the NEC is application specific. You need the parts that relate to your job, clearly organized so you can find what you need, and geared to what you do. This book is the 2002 NEC for the installer, with easy-to-follow chapter headings to help you find important information quickly, and explanations that make sense. You'll want it with you on every job.\u003cbr\u003e * Find those parts of the NEC that matter to your job - nothing more\u003cbr\u003e * Understand all general and basic requirements \u003cbr\u003e * Identify specific standards for multiple buildings sharing service\u003cbr\u003e * Know the rules regarding surge arrestors, grounding connections for AC systems, and grounding for separately derived systems\u003cbr\u003e * Review the requirements for wiring in all types of cable and conduit\u003cbr\u003e * Look into code requirements for specialized applications like hospitals, motion picture studios and theaters, RV parks, and swimming pools  \u003cb\u003eIntroduction.\u003c\/b\u003e  \u003cp\u003e\u003cb\u003eChapter 1: General Requirements.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eGeneral Requirements (Article 110).\u003c\/p\u003e \u003cp\u003eBasic Requirements (Article 110).\u003c\/p\u003e \u003cp\u003eUse of Grounded Conductors (Article 200).\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 2: Branch Circuits.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eBranch Circuits (Article 210).\u003c\/p\u003e \u003cp\u003eClassifications.\u003c\/p\u003e \u003cp\u003eGrounded Conductors.\u003c\/p\u003e \u003cp\u003eVoltages.\u003c\/p\u003e \u003cp\u003eReceptacles and Cord Connectors.\u003c\/p\u003e \u003cp\u003eGround-Fault Circuit Interrupters.\u003c\/p\u003e \u003cp\u003eArc-Fault Circuit Interrupters.\u003c\/p\u003e \u003cp\u003eBranch-Circuit Ratings.\u003c\/p\u003e \u003cp\u003eAppliance Outlets.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 3: Feeders.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eFeeders (Article 215).\u003c\/p\u003e \u003cp\u003eRatings and Sizes.\u003c\/p\u003e \u003cp\u003eGrounding and Other Requirements.\u003c\/p\u003e \u003cp\u003eOutdoor Feeders or Branch Circuits.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 4: Services.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eServices (Article 230).\u003c\/p\u003e \u003cp\u003eService Conductors.\u003c\/p\u003e \u003cp\u003eService Clearances.\u003c\/p\u003e \u003cp\u003eUnderground Service Conductors.\u003c\/p\u003e \u003cp\u003eWiring Methods.\u003c\/p\u003e \u003cp\u003eService Equipment.\u003c\/p\u003e \u003cp\u003eOvercurrent Protection.\u003c\/p\u003e \u003cp\u003eServices Over 600 Volts.\u003c\/p\u003e \u003cp\u003e\u003cb\u003e;Chapter 5: Overcurrent Protection.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eOvercurrent Protection (Article 240).\u003c\/p\u003e \u003cp\u003eTaps.\u003c\/p\u003e \u003cp\u003eLocations.\u003c\/p\u003e \u003cp\u003eFuses and Circuit Breakers.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 6: Grounding.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eGrounding (Article 250).\u003c\/p\u003e \u003cp\u003eCircuit and System Grounding.\u003c\/p\u003e \u003cp\u003eLocation of Grounding Conductors.\u003c\/p\u003e \u003cp\u003eAC System Grounding Connections.\u003c\/p\u003e \u003cp\u003eTwo or More Buildings Supplied by a Common Service.\u003c\/p\u003e \u003cp\u003eDisconnecting Means Located in Separate Building on Same Premises.\u003c\/p\u003e \u003cp\u003eConductor to Be Grounded.\u003c\/p\u003e \u003cp\u003eGrounding for Separately Derived Systems.\u003c\/p\u003e \u003cp\u003eHigh-Impedance Grounded Neutral Connections.\u003c\/p\u003e \u003cp\u003eGrounding of Enclosures.\u003c\/p\u003e \u003cp\u003eEquipment Grounding.\u003c\/p\u003e \u003cp\u003eMethods of Grounding.\u003c\/p\u003e \u003cp\u003eBonding.\u003c\/p\u003e \u003cp\u003eGrounding Electrode Systems.\u003c\/p\u003e \u003cp\u003eGrounding Conductors.\u003c\/p\u003e \u003cp\u003eGrounding Conductor Connections.\u003c\/p\u003e \u003cp\u003eIsolated Grounding.\u003c\/p\u003e \u003cp\u003eOther Requirements.\u003c\/p\u003e \u003cp\u003eSurge Arrestors (Article 280).\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 7: Wiring Requirements.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eWiring Methods (Article 300).\u003c\/p\u003e \u003cp\u003eGeneral.\u003c\/p\u003e \u003cp\u003eProtection of Conductors.\u003c\/p\u003e \u003cp\u003eUnderground Wiring.\u003c\/p\u003e \u003cp\u003eRaceways.\u003c\/p\u003e \u003cp\u003eBoxes.\u003c\/p\u003e \u003cp\u003eConductors.\u003c\/p\u003e \u003cp\u003eTemporary Wiring (Article 527).\u003c\/p\u003e \u003cp\u003eConductors for General Wiring (Article 310).\u003c\/p\u003e \u003cp\u003eIdentification of Conductors.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 8: Wiring in Cable.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eCable Tray Systems (Article 392).\u003c\/p\u003e \u003cp\u003eUses and Locations.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eCable Installation.\u003c\/p\u003e \u003cp\u003eNumber of Cables.\u003c\/p\u003e \u003cp\u003eAmpacities of Conductors.\u003c\/p\u003e \u003cp\u003eOpen Wiring on Insulators (Article 398).\u003c\/p\u003e \u003cp\u003eUses Permitted.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eMessenger-Supported Wiring (Article 396).\u003c\/p\u003e \u003cp\u003eUses and Locations.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eConcealed Knob-and-Tube Wiring (Article 394).\u003c\/p\u003e \u003cp\u003eUses and Locations.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eIntegrated Gas Spacer Cable (Article 326).\u003c\/p\u003e \u003cp\u003eUses and Locations.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eMedium-Voltage Cable (Article 328).\u003c\/p\u003e \u003cp\u003eUses and Locations.\u003c\/p\u003e \u003cp\u003eFlat Conductor Cable (Article 324).\u003c\/p\u003e \u003cp\u003eUses and Locations.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eMineral-Insulated Metal-Sheathed Cable (Article 332).\u003c\/p\u003e \u003cp\u003eUses and Locations.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eArmored Cable (Article 320).\u003c\/p\u003e \u003cp\u003eUses and Locations.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eMetal-Clad Cable (Article 330).\u003c\/p\u003e \u003cp\u003eUses and Locations.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eNonmetallic-Sheathed Cable (Article 334).\u003c\/p\u003e \u003cp\u003eUses and Locations.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eType NMS.\u003c\/p\u003e \u003cp\u003eUses and Locations.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eService-Entrance Cable (Article 338).\u003c\/p\u003e \u003cp\u003eUses Permitted.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eUnderground Feeder and Branch-Circuit Cable (Article 340).\u003c\/p\u003e \u003cp\u003eUses and Locations.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003ePower and Control Tray Cable (Article 336).\u003c\/p\u003e \u003cp\u003eUses and Locations.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eNonmetallic Extensions (Article 382).\u003c\/p\u003e \u003cp\u003eUses and Locations.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eFlat Cable Assemblies (Article 322).\u003c\/p\u003e \u003cp\u003eUses and Locations.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 9: Wiring in Conduit.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eElectrical Metallic Tubing (EMT, Thin-Wall) (Article 358).\u003c\/p\u003e \u003cp\u003eUses and Locations.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eWire Fills.\u003c\/p\u003e \u003cp\u003eRigid Metal Conduit (RMC or Heavy-Wall) (Article 344).\u003c\/p\u003e \u003cp\u003eUses and Locations.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eWire Fills.\u003c\/p\u003e \u003cp\u003eIntermediate Metal Conduit (IMC) (Article 342).\u003c\/p\u003e \u003cp\u003eUses and Locations.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eWire Fills.\u003c\/p\u003e \u003cp\u003eRigid Nonmetallic Conduit (RNC) (Article 352).\u003c\/p\u003e \u003cp\u003eUses and Locations.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eWire Fills.\u003c\/p\u003e \u003cp\u003eFlexible Metal Conduit (Greenfield or Flex) (Article 348).\u003c\/p\u003e \u003cp\u003eUses and Locations.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eWire Fills.\u003c\/p\u003e \u003cp\u003eFlexible Metallic Tubing (Article 360).\u003c\/p\u003e \u003cp\u003eUses and Locations.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eWire Fills.\u003c\/p\u003e \u003cp\u003eLiquid-Tight Flexible Metallic Conduit (LFMC) (Article 350).\u003c\/p\u003e \u003cp\u003eUses and Locations.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eWire Fills.\u003c\/p\u003e \u003cp\u003eLiquid-Tight Flexible Nonmetallic Conduit (LFNC) (Article 356).\u003c\/p\u003e \u003cp\u003eUses and Locations.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eWire Fills.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 10: Raceways and Wireways.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eSurface Metal Raceways (Article 386).\u003c\/p\u003e \u003cp\u003eUses and Locations.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eWire Fills.\u003c\/p\u003e \u003cp\u003eSurface Nonmetallic Raceways (Article 388).\u003c\/p\u003e \u003cp\u003eUses and Locations.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eWire Fills.\u003c\/p\u003e \u003cp\u003eMulti-Outlet Assemblies (Article 380).\u003c\/p\u003e \u003cp\u003eUses and Locations.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eUnderfloor Raceways (Article 390).\u003c\/p\u003e \u003cp\u003eUses and Locations.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eWire Fills.\u003c\/p\u003e \u003cp\u003eCellular Metal Floor Raceways (Article 374).\u003c\/p\u003e \u003cp\u003eDescription.\u003c\/p\u003e \u003cp\u003eWhere Not Permitted.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eWire Fills.\u003c\/p\u003e \u003cp\u003eCellular Concrete Floor Raceways (Article 372).\u003c\/p\u003e \u003cp\u003eDescription.\u003c\/p\u003e \u003cp\u003eWhere Not Permitted.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eWire Fills.\u003c\/p\u003e \u003cp\u003eMetal Wireways (Article 376).\u003c\/p\u003e \u003cp\u003eUses and Locations.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eWire Fills.\u003c\/p\u003e \u003cp\u003eAuxiliary Gutters (Article 366).\u003c\/p\u003e \u003cp\u003eDescription.\u003c\/p\u003e \u003cp\u003eUses.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eWire Fills.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 11: Busways.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eBusways (Busduct) (Article 368).\u003c\/p\u003e \u003cp\u003eUses and Locations.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eCablebus (Article 370).\u003c\/p\u003e \u003cp\u003eUses and Locations.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 12: Outlet and Pull Boxes.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eOutlet, Device, Pull, and Junction Boxes; Conduit Bodies, Fittings, and Manholes (Article 314).\u003c\/p\u003e \u003cp\u003eUses.\u003c\/p\u003e \u003cp\u003eWire Fills.\u003c\/p\u003e \u003cp\u003ePull Boxes.\u003c\/p\u003e \u003cp\u003eCabinets and Cutout Boxes (Article 312).\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 13: Switches and Switchboards.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eSwitches (Article 404).\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eKnife Switches.\u003c\/p\u003e \u003cp\u003eSwitchboards and Panelboards (Article 408).\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 14: Cords.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eFlexible Cords and Cables (Article 400).\u003c\/p\u003e \u003cp\u003eUses.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003ePortable Cables Over 600 Volts.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 15: Lighting Fixtures.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eLighting Fixtures, Lampholders, and Lamps (Article 410).\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eFixtures in Clothes Closets.\u003c\/p\u003e \u003cp\u003eTrack Lighting.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 16: Receptacles.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eReceptacles, Cord Connectors, and Attachment Plugs (Article 406).\u003c\/p\u003e \u003cp\u003eReceptacles.\u003c\/p\u003e \u003cp\u003eAttachment Plugs and Cord Connectors.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 17: Appliances.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eAppliances (Article 422).\u003c\/p\u003e \u003cp\u003eBranch Circuits.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eFixed Electric Space-Heating Equipment (Article 424).\u003c\/p\u003e \u003cp\u003eBranch Circuits.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eElectric Space-Heating Cables.\u003c\/p\u003e \u003cp\u003eDuct Heaters.\u003c\/p\u003e \u003cp\u003eIce and Snow Melting Equipment (Article 426).\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 18: Motors and Controllers.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eMotor Circuits, Controllers (Article 430).\u003c\/p\u003e \u003cp\u003eAdjustable-Speed Drive Systems.\u003c\/p\u003e \u003cp\u003ePart-Winding Motors.\u003c\/p\u003e \u003cp\u003eMotor Ratings and Ampacity Ratings.\u003c\/p\u003e \u003cp\u003eTorque Motors.\u003c\/p\u003e \u003cp\u003eAC Adjustable-Voltage Motors.\u003c\/p\u003e \u003cp\u003eMotor Locations.\u003c\/p\u003e \u003cp\u003eMotor Circuit Conductors.\u003c\/p\u003e \u003cp\u003eConductors Supplying Several Motors or Phase Converters.\u003c\/p\u003e \u003cp\u003eConductors Supplying Motors and Other Loads.\u003c\/p\u003e \u003cp\u003eOverload Protection.\u003c\/p\u003e \u003cp\u003eShort-Circuit and Ground-Fault Protection.\u003c\/p\u003e \u003cp\u003eMotor Control Circuits.\u003c\/p\u003e \u003cp\u003eMotor Controllers.\u003c\/p\u003e \u003cp\u003eGrounding.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 19: HVAC Equipment.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eAir-Conditioning and Refrigeration Equipment (Article 440).\u003c\/p\u003e \u003cp\u003eDisconnecting Means.\u003c\/p\u003e \u003cp\u003eBranch Circuits.\u003c\/p\u003e \u003cp\u003eControllers and Overload Protection.\u003c\/p\u003e \u003cp\u003eRoom Air Conditioners.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 20: Generators.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eGenerators (Article 445).\u003c\/p\u003e \u003cp\u003eLocations.\u003c\/p\u003e \u003cp\u003eOvercurrent Protection.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 21: Transformers.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eTransformers (Article 450).\u003c\/p\u003e \u003cp\u003eOvercurrent Protection.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 22: Capacitors, Resistors, and Batteries.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eCapacitors (Article 460).\u003c\/p\u003e \u003cp\u003eConductors.\u003c\/p\u003e \u003cp\u003eResistors and Reactors (Article 470).\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eStorage Batteries (Article 480).\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 23: Hazardous Locations.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eHazardous Locations (Articles 500, 501, 502, 503, 504).\u003c\/p\u003e \u003cp\u003eGeneral.\u003c\/p\u003e \u003cp\u003eClass I Locations.\u003c\/p\u003e \u003cp\u003eClass II Locations.\u003c\/p\u003e \u003cp\u003eClass III Locations.\u003c\/p\u003e \u003cp\u003eIntrinsically Safe Systems.\u003c\/p\u003e \u003cp\u003eCommercial Garages (Article 511).\u003c\/p\u003e \u003cp\u003eAirplane Hangars (Article 513).\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 24: Service Stations.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eGasoline Dispensing and Service Stations (Article 514).\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 25: Bulk Storage Plants.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eBulk Storage Plants (Article 515).\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 26: Spray Areas.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eSpray Application, Dipping, and Coating Processes (Article 516).\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 27: Health Care Facilities.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eHealth Care Facilities (Article 517).\u003c\/p\u003e \u003cp\u003eGeneral Areas.\u003c\/p\u003e \u003cp\u003ePatient Care Areas.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 28: Places of Assembly, Theaters, Motion Picture and Television Studios.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003ePlaces of Assembly (Article 518).\u003c\/p\u003e \u003cp\u003eTheaters (Article 520).\u003c\/p\u003e \u003cp\u003eMotion Picture and Television Studios (Article 530).\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 29: Signs.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 30: Manufactured Wiring Systems.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eManufactured Wiring Systems (Article 604).\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eOffice Furnishings (Article 605).\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 31: Mobile Homes and RV Parks.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eMobile Homes (Article 550).\u003c\/p\u003e \u003cp\u003eService Equipment.\u003c\/p\u003e \u003cp\u003ePower Supply.\u003c\/p\u003e \u003cp\u003eDisconnecting Means.\u003c\/p\u003e \u003cp\u003eBranch Circuits.\u003c\/p\u003e \u003cp\u003eReceptacles.\u003c\/p\u003e \u003cp\u003eGrounding.\u003c\/p\u003e \u003cp\u003eRecreational Vehicle Parks (Article 551).\u003c\/p\u003e \u003cp\u003eElectric Service at Sites.\u003c\/p\u003e \u003cp\u003eDistribution.\u003c\/p\u003e \u003cp\u003eSupply Equipment.\u003c\/p\u003e \u003cp\u003eUnderground Service, Feeder, and Branch-Circuit Conductors.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 32: Data Processing Areas.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eInformation Technology Equipment (Article 645).\u003c\/p\u003e \u003cp\u003eApplication.\u003c\/p\u003e \u003cp\u003eSupply Circuits and Cables.\u003c\/p\u003e \u003cp\u003ePower.\u003c\/p\u003e \u003cp\u003eGrounding.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 33: Swimming Pools.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eSwimming Pools (Article 680).\u003c\/p\u003e \u003cp\u003ePower Supply and Circuits.\u003c\/p\u003e \u003cp\u003eUnderwater Lighting.\u003c\/p\u003e \u003cp\u003eBonding.\u003c\/p\u003e \u003cp\u003eUnderwater Audio Equipment.\u003c\/p\u003e \u003cp\u003eGrounding Requirements.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 34: Solar Electric Systems.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eSolar Photovoltaic Systems (Article 690).\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eDisconnecting Means.\u003c\/p\u003e \u003cp\u003eWiring.\u003c\/p\u003e \u003cp\u003eGrounding.\u003c\/p\u003e \u003cp\u003eSource Connections.\u003c\/p\u003e \u003cp\u003eStorage Batteries.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 35 Emergency Systems.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eEmergency Systems (Article 700).\u003c\/p\u003e \u003cp\u003eCircuit Wiring.\u003c\/p\u003e \u003cp\u003eLegally Required Standby Systems (Article 701).\u003c\/p\u003e \u003cp\u003eOptional Standby Systems (Article 702).\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 36 High Voltage.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eWiring Over 600 Volts (Article 490).\u003c\/p\u003e \u003cp\u003eWiring Methods.\u003c\/p\u003e \u003cp\u003eUnderground Conductors.\u003c\/p\u003e \u003cp\u003eEquipment.\u003c\/p\u003e \u003cp\u003eElectrode-Type Boilers.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 37: Low Voltage.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eCircuits and Equipment Operating at Less Than 50 Volts (Article 720).\u003c\/p\u003e \u003cp\u003eClass 1, 2, or 3 Remote-Control, Signaling, and Power-Limited Circuits (Article 725).\u003c\/p\u003e \u003cp\u003eClassifications.\u003c\/p\u003e \u003cp\u003eClass 1 Circuits.\u003c\/p\u003e \u003cp\u003eClass 2 and Class 3 Circuits.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 38: Fiber-Optic Cables.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eOptical Fiber Cables (Article 770).\u003c\/p\u003e \u003cp\u003eBrief Explanation.\u003c\/p\u003e \u003cp\u003eInstallation.\u003c\/p\u003e \u003cp\u003eTypes and Uses.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 39: Communications.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eCommunications Systems (Article 800).\u003c\/p\u003e \u003cp\u003eConductors Entering Buildings.\u003c\/p\u003e \u003cp\u003eProtection.\u003c\/p\u003e \u003cp\u003eCommunications Conductors in Buildings.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChapter 40: Special Installations.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eLightning Protection Systems (Not in NEC).\u003c\/p\u003e \u003cp\u003eClosed-Loop and Programmed Power Distribution (Article 780).\u003c\/p\u003e \u003cp\u003eRadio and Television Equipment (Article 810).\u003c\/p\u003e \u003cp\u003eCommunity Antenna TV and Radio Distribution Systems (Article 820).\u003c\/p\u003e \u003cp\u003eFire Alarm Systems (Article 760).\u003c\/p\u003e \u003cp\u003eInterconnected Electrical Power Sources (Article 705).\u003c\/p\u003e \u003cp\u003eIrrigation Machines (Article 675).\u003c\/p\u003e \u003cp\u003eIndustrial Machinery (Article 670).\u003c\/p\u003e \u003cp\u003eElectroplating (Article 669).\u003c\/p\u003e \u003cp\u003eElectrolytic Cells (Article 668).\u003c\/p\u003e \u003cp\u003ePipe Organs (Article 650).\u003c\/p\u003e \u003cp\u003eX-Ray Equipment (Article 660).\u003c\/p\u003e \u003cp\u003eInduction Heating Equipment (Article 665).\u003c\/p\u003e \u003cp\u003eSound Recording Equipment (Article 640).\u003c\/p\u003e \u003cp\u003eElectric Welders (Article 630).\u003c\/p\u003e \u003cp\u003eElevators (Article 620).\u003c\/p\u003e \u003cp\u003eMarinas and Boatyards (Article 555).\u003c\/p\u003e \u003cp\u003eAgricultural Buildings (Article 547).\u003c\/p\u003e \u003cp\u003eFloating Buildings (Article 553).\u003c\/p\u003e \u003cp\u003e\u003cb\u003eGlossary.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003e\u003cb\u003eIndex.\u003c\/b\u003e\u003c\/p\u003e Paul Rosenberg is a master electrician and a leading voice in the electrical industry. An instructor at Iowa State University, he has written training courses for NECA and articles for all major industry publications as well as Audel Electricians Pocket Manual, 2nd Edition.   A practical guide to the 2002 NEC  \u003cp\u003eAs an electrician, your interest in the NEC is application specific. You need the parts that relate to your job, clearly organized so you can find what you need, and geared to what you do. This book is the 2002 NEC for the installer, with easy-to-follow chapter headings to help you find important information quickly, and explanations that make sense. Youll want it with you on every job.\u003c\/p\u003e \u003cul\u003e \u003cli\u003eFind those parts of the NEC that matter to your job  nothing more\u003c\/li\u003e \u003cli\u003eUnderstand all general and basic requirements\u003c\/li\u003e \u003cli\u003eIdentify specific standards for multiple buildings sharing service\u003c\/li\u003e \u003cli\u003eKnow the rules regarding surge arrestors, grounding connections for AC systems, and grounding for separately derived systems\u003c\/li\u003e \u003cli\u003eReview the requirements for wiring in all types of cable and conduit\u003c\/li\u003e \u003cli\u003eLook into code requirements for specialized applications like hospitals, motion picture studios and theaters, RV parks, and swimming pools\u003c\/li\u003e \u003c\/ul\u003e","brand":"Audel","offers":[{"title":"Default Title","offer_id":47988776370405,"sku":"NP9780764542787","price":36.5,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1842\/7735\/files\/9780764542787.jpg?v=1761781548","url":"https:\/\/k12savings.com\/products\/audel-installation-requirements-of-the-2002-national-electrical-code-isbn-9780764542787","provider":"K12savings","version":"1.0","type":"link"}