{"product_id":"indoor-radio-planning-isbn-9781118913628","title":"Indoor Radio Planning","description":"Why is high performance indoor wireless service needed, and how is it best implemented? As the challenge of providing better service and higher data speeds and quality for mobile applications intensifies, ensuring adequate in-building and tunnel coverage and capacity is increasingly important. A unique, single-source reference on the theoretical and practical knowledge behind indoor and tunnel radio planning, this book provides a detailed overview of mobile networks systems, coverage and capacity solutions with 2G, 3G and 4G cellular system technologies as a backdrop. \u003cp\u003e\u003cb\u003e\u003ci\u003eForeword by Professor Simon Saunders xvii\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003e\u003cb\u003e\u003ci\u003ePreface to the Third Edition xix\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e7 years! xix\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003eCertified DAS Planning Training xix\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003eMore on 4G, Small Cells, Applications and RF Basics xx\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003eUseful Tool? xx\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003eThanks! xx\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003cb\u003e\u003ci\u003ePreface to the Second Edition xxi\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003eThis is Still Not a Book for Scientists! xxi\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003eThe Practical Approach xxii\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003eKeep the Originals! xxii\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003cb\u003e\u003ci\u003ePreface to the First Edition xxiii\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003eThis is Not a Book for Scientists xxiii\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003eThe Practical Approach xxiii\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003cb\u003e\u003ci\u003eAcknowledgments xxv\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003eSecond Edition xxv\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003eFirst Edition xxvi\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003cb\u003e\u003ci\u003e1 Introduction 1\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003e\u003cb\u003e\u003ci\u003e2 Overview of Cellular Systems 5\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.1 Mobile Telephony 5\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.1.1 Cellular Systems \u003c\/i\u003e\u003ci\u003e5\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.1.2 Radio Transmission in General \u003c\/i\u003e\u003ci\u003e8\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.1.3 The Cellular Concept \u003c\/i\u003e\u003ci\u003e8\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.1.4 Digital Cellular Systems \u003c\/i\u003e\u003ci\u003e9\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.2 Introduction to GSM (2G) 10\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.2.1 GSM (2G) \u003c\/i\u003e\u003ci\u003e10\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.2.2 2G\/GSM Radio Features \u003c\/i\u003e\u003ci\u003e11\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.2.3 Mobility Management in GSM \u003c\/i\u003e\u003ci\u003e16\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.2.4 GSM Signaling \u003c\/i\u003e\u003ci\u003e22\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.2.5 GSM Network Architecture \u003c\/i\u003e\u003ci\u003e25\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.3 Universal Mobile Telecommunication System\/3G 27\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.3.1 The Most Important 3G\/UMTS Radio Design Parameters \u003c\/i\u003e\u003ci\u003e28\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.3.2 The 3G\/UMTS Radio Features \u003c\/i\u003e\u003ci\u003e28\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.3.3 3G\/UMTS Noise Control \u003c\/i\u003e\u003ci\u003e38\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.3.4 3G\/UMTS Handovers \u003c\/i\u003e\u003ci\u003e42\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.3.5 UMTS\/3G Power Control \u003c\/i\u003e\u003ci\u003e46\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.3.6 UMTS and Multipath Propagation \u003c\/i\u003e\u003ci\u003e49\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.3.7 UMTS Signaling \u003c\/i\u003e\u003ci\u003e52\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.3.8 The UMTS Network Elements \u003c\/i\u003e\u003ci\u003e55\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.4 Introduction to HSPA 57\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.4.1 Introduction \u003c\/i\u003e\u003ci\u003e57\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.4.2 Wi\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003eFi \u003c\/i\u003e\u003ci\u003e58\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.4.3 Introduction to HSDPA \u003c\/i\u003e\u003ci\u003e60\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.4.4 Indoor HSPA Coverage \u003c\/i\u003e\u003ci\u003e61\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.4.5 Indoor HSPA Planning for Maximum Performance \u003c\/i\u003e\u003ci\u003e63\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.4.6 HSDPA Coverage from the Macro Network \u003c\/i\u003e\u003ci\u003e64\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.4.7 Passive DAS and HSPA \u003c\/i\u003e\u003ci\u003e66\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.4.8 Short Introduction to HSPA+ \u003c\/i\u003e\u003ci\u003e68\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.4.9 Conclusion \u003c\/i\u003e\u003ci\u003e68\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.5 Modulation 69\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.5.1 Shannon’s Formula \u003c\/i\u003e\u003ci\u003e69\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.5.2 BPSK \u003c\/i\u003e\u003ci\u003e70\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.5.3 QPSK – Quadrature Phase Shift Keying \u003c\/i\u003e\u003ci\u003e70\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.5.4 Higher Order Modulation 16\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003e64QAM \u003c\/i\u003e\u003ci\u003e70\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.5.5 EVM Error Vector Magnitude \u003c\/i\u003e\u003ci\u003e72\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.5.6 Adaptive Modulation, Planning for Highest Data Speed \u003c\/i\u003e\u003ci\u003e72\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.6 Advanced Antenna Systems for 3G\/4G 74\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.6.1 SISO\/MIMO Systems \u003c\/i\u003e\u003ci\u003e75\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.6.2 SISO, Single Input Single Output \u003c\/i\u003e\u003ci\u003e75\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.6.3 SIMO, Single Input Multiple Output \u003c\/i\u003e\u003ci\u003e76\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.6.4 MISO, Multiple Inputs Single Output \u003c\/i\u003e\u003ci\u003e76\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.6.5 MIMO, Multiple Inputs Multiple Outputs \u003c\/i\u003e\u003ci\u003e77\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.6.6 Planning for Optimum Data Speeds Using MIMO \u003c\/i\u003e\u003ci\u003e79\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.7 Short Introduction to 4G\/LTE 80\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.7.1 Motivation behind LTE and E\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003eUTRAN \u003c\/i\u003e\u003ci\u003e80\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.7.2 Key Features of LTE E\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003eUTRAN \u003c\/i\u003e\u003ci\u003e82\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.7.3 System Architecture Evolution – SAE \u003c\/i\u003e\u003ci\u003e84\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.7.4 EPS – Evolved Packet System \u003c\/i\u003e\u003ci\u003e84\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.7.5 Evolved Packet Core Network – EPC \u003c\/i\u003e\u003ci\u003e85\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.7.6 LTE Reference Points\/Interfaces \u003c\/i\u003e\u003ci\u003e87\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.7.7 The LTE RF Channel Bandwidth \u003c\/i\u003e\u003ci\u003e87\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.7.8 OFDM – Orthogonal Frequency Division Multiplexing \u003c\/i\u003e\u003ci\u003e88\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.7.9 OFDMA – Orthogonal Frequency Division Multiple Access \u003c\/i\u003e\u003ci\u003e89\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.7.10 SC\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003eFDMA – Single Carrier Frequency Division Multiple Access \u003c\/i\u003e\u003ci\u003e90\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.7.11 LTE Slot Structure \u003c\/i\u003e\u003ci\u003e91\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.7.12 User Scheduling \u003c\/i\u003e\u003ci\u003e92\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.7.13 Downlink Reference Signals \u003c\/i\u003e\u003ci\u003e92\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.7.14 The 4G\/LTE Channel \u003c\/i\u003e\u003ci\u003e92\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.7.15 LTE Communication and Control Channels \u003c\/i\u003e\u003ci\u003e93\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e2.7.16 Radio Resource Management in LTE \u003c\/i\u003e\u003ci\u003e96\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003cb\u003e\u003ci\u003e3 Indoor Radio Planning 111\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.1 Why is In\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003ebuilding Coverage Important? 111\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.1.1 Commercial and Technical Evaluation \u003c\/i\u003e\u003ci\u003e112\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.1.2 The Main Part of the Mobile Traffic is Indoors \u003c\/i\u003e\u003ci\u003e112\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.1.3 Some 70–80% of Mobile Traffic is Inside Buildings \u003c\/i\u003e\u003ci\u003e112\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.1.4 Indoor Solutions Can Make a Great Business Case \u003c\/i\u003e\u003ci\u003e112\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.1.5 Business Evaluation \u003c\/i\u003e\u003ci\u003e113\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.1.6 Coverage Levels\/Cost Level \u003c\/i\u003e\u003ci\u003e113\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.1.7 Evaluate the Value of the Proposed Solution \u003c\/i\u003e\u003ci\u003e113\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.2 Indoor Coverage from the Macro Layer 114\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.2.1 More Revenue with Indoor Solutions \u003c\/i\u003e\u003ci\u003e114\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.2.2 The Problem Reaching Indoor Mobile Users \u003c\/i\u003e\u003ci\u003e115\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.3 The Indoor 3G\/HSPA Challenge 117\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.3.1 3G Orthogonality Degradation \u003c\/i\u003e\u003ci\u003e117\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.3.2 Power Load per User \u003c\/i\u003e\u003ci\u003e120\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.3.3 Interference Control in the Building \u003c\/i\u003e\u003ci\u003e120\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.3.4 The Soft Handover Load \u003c\/i\u003e\u003ci\u003e120\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.3.5 3G\/HSPA Indoor Coverage Conclusion \u003c\/i\u003e\u003ci\u003e121\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.4 Common 3G\/4G Rollout Mistakes 122\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.4.1 The Macro Mistake \u003c\/i\u003e\u003ci\u003e122\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.4.2 Do Not Apply 2G Strategies \u003c\/i\u003e\u003ci\u003e123\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.4.3 The Correct Way to Plan 3G\/4G Indoor Coverage \u003c\/i\u003e\u003ci\u003e123\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.5 The Basics of Indoor RF Planning 124\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.5.1 Isolation is the Key \u003c\/i\u003e\u003ci\u003e124\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.5.2 Tinted Windows Will Help Isolation \u003c\/i\u003e\u003ci\u003e124\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.5.3 The ‘High\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003erise Problem’ \u003c\/i\u003e\u003ci\u003e125\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.5.4 Radio Service Quality \u003c\/i\u003e\u003ci\u003e128\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.5.5 Indoor RF Design Levels \u003c\/i\u003e\u003ci\u003e129\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.5.6 The Zone Planning Concept \u003c\/i\u003e\u003ci\u003e129\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.6 RF Metrics Basics 131\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.6.1 Gain \u003c\/i\u003e\u003ci\u003e132\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.6.2 Gain Factor \u003c\/i\u003e\u003ci\u003e132\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.6.3 Decibel (dB) \u003c\/i\u003e\u003ci\u003e133\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.6.4 dBm \u003c\/i\u003e\u003ci\u003e135\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.6.5 Equivalent Isotropic Radiated Power (EiRP) \u003c\/i\u003e\u003ci\u003e136\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.6.6 Delays in the DAS \u003c\/i\u003e\u003ci\u003e136\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e3.6.7 Offset of the Cell Size \u003c\/i\u003e\u003ci\u003e139\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003cb\u003e\u003ci\u003e4 Distributed Antenna Systems 141\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.1 What Type of Distributed Antenna System is Best? 141\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.1.1 Passive or Active DAS \u003c\/i\u003e\u003ci\u003e142\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.1.2 Learn to Use all the Indoor Tools \u003c\/i\u003e\u003ci\u003e142\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.1.3 Combine the Tools \u003c\/i\u003e\u003ci\u003e143\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.2 Passive Components 143\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.2.1 General \u003c\/i\u003e\u003ci\u003e143\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.2.2 Coax Cable \u003c\/i\u003e\u003ci\u003e143\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.2.3 Splitters \u003c\/i\u003e\u003ci\u003e144\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.2.4 Taps\/Uneven Splitters \u003c\/i\u003e\u003ci\u003e145\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.2.5 Attenuators \u003c\/i\u003e\u003ci\u003e146\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.2.6 Dummy Loads or Terminators \u003c\/i\u003e\u003ci\u003e147\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.2.7 Circulators \u003c\/i\u003e\u003ci\u003e147\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.2.8 A 3 dB Coupler (90° Hybrid) \u003c\/i\u003e\u003ci\u003e148\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.2.9 Power Load on Passive Components \u003c\/i\u003e\u003ci\u003e150\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.2.10 Filters \u003c\/i\u003e\u003ci\u003e151\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.3 The Passive DAS 151\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.3.1 Planning the Passive DAS \u003c\/i\u003e\u003ci\u003e151\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.3.2 Main Points About Passive DAS \u003c\/i\u003e\u003ci\u003e153\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.3.3 Applications for Passive DAS \u003c\/i\u003e\u003ci\u003e154\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.4 Active DAS 154\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.4.1 Easy to Plan \u003c\/i\u003e\u003ci\u003e155\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.4.2 Pure Active DAS for Large Buildings \u003c\/i\u003e\u003ci\u003e155\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.4.3 Pure Active DAS for Small to Medium\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003esize Buildings \u003c\/i\u003e\u003ci\u003e159\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.4.4 Active Fiber DAS \u003c\/i\u003e\u003ci\u003e160\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.5 Hybrid Active DAS Solutions 163\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.5.1 Data Performance on the Uplink \u003c\/i\u003e\u003ci\u003e163\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.5.2 DL Antenna Power \u003c\/i\u003e\u003ci\u003e163\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.5.3 Antenna Supervision \u003c\/i\u003e\u003ci\u003e164\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.5.4 Installation Challenges \u003c\/i\u003e\u003ci\u003e164\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.5.5 The Elements of the Hybrid Active DAS \u003c\/i\u003e\u003ci\u003e164\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.6 Other Hybrid DAS Solutions 166\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.6.1 In\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003eline BDA Solution \u003c\/i\u003e\u003ci\u003e166\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.6.2 Combining Passive and Active Indoor DAS \u003c\/i\u003e\u003ci\u003e167\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.6.3 Combining Indoor and Outdoor Coverage \u003c\/i\u003e\u003ci\u003e168\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.7 Indoor DAS for MIMO Applications 171\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.7.1 Calculating the Ideal MIMO Antenna Distance Separation for Indoor DAS \u003c\/i\u003e\u003ci\u003e171\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.7.2 Make Both MIMO Antennas ‘Visible’ for the Users \u003c\/i\u003e\u003ci\u003e173\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.7.3 Passive DAS and MIMO \u003c\/i\u003e\u003ci\u003e178\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.7.4 Pure Active DAS for MIMO \u003c\/i\u003e\u003ci\u003e179\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.7.5 Hybrid DAS and MIMO \u003c\/i\u003e\u003ci\u003e181\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.7.6 Upgrading Existing DAS to MIMO \u003c\/i\u003e\u003ci\u003e181\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.8 Using Repeaters for Indoor DAS Coverage 182\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.8.1 Basic Repeater Terms \u003c\/i\u003e\u003ci\u003e184\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.8.2 Repeater Types \u003c\/i\u003e\u003ci\u003e189\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.8.3 Repeater Considerations in General \u003c\/i\u003e\u003ci\u003e192\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.9 Repeaters for Rail Solutions 195\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.9.1 Repeater Principle on a Train \u003c\/i\u003e\u003ci\u003e195\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.9.2 Onboard DAS Solutions \u003c\/i\u003e\u003ci\u003e197\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.9.3 Repeater Features for Mobile Rail Deployment \u003c\/i\u003e\u003ci\u003e197\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.9.4 Practical Concerns with Repeaters on Rail \u003c\/i\u003e\u003ci\u003e199\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.10 Active DAS Data 200\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.10.1 Gain and Delay \u003c\/i\u003e\u003ci\u003e201\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.10.2 Power Per Carrier \u003c\/i\u003e\u003ci\u003e202\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.10.3 Bandwidth, Ripple \u003c\/i\u003e\u003ci\u003e202\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.10.4 The 1 dB Compression Point \u003c\/i\u003e\u003ci\u003e203\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.10.5 IP3 Third\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003eorder Intercept Point \u003c\/i\u003e\u003ci\u003e204\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.10.6 Harmonic Distortion, Inter\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003emodulation \u003c\/i\u003e\u003ci\u003e205\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.10.7 Spurious Emissions \u003c\/i\u003e\u003ci\u003e205\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.10.8 Noise Figure \u003c\/i\u003e\u003ci\u003e205\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.10.9 MTBF \u003c\/i\u003e\u003ci\u003e206\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.10.10 Dynamic Range and Near\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003efar Effect \u003c\/i\u003e\u003ci\u003e207\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.11 Electromagnetic Radiation, EMR 211\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.11.1 ICNIRP EMR Guidelines \u003c\/i\u003e\u003ci\u003e211\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.11.2 Mobiles are the Strongest Source of EMR \u003c\/i\u003e\u003ci\u003e212\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.11.3 Indoor DAS will Provide Lower EMR Levels \u003c\/i\u003e\u003ci\u003e213\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e4.12 Conclusion 214\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003cb\u003e\u003ci\u003e5 Designing Indoor DAS Solutions 215\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.1 The Indoor Planning Procedure 215\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.1.1 Indoor Planning Process Flow \u003c\/i\u003e\u003ci\u003e215\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.1.2 The RF Planning Part of the Process \u003c\/i\u003e\u003ci\u003e217\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.1.3 The Site Survey \u003c\/i\u003e\u003ci\u003e218\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.1.4 Time Frame for Implementing Indoor DAS \u003c\/i\u003e\u003ci\u003e219\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.1.5 Post Implementation \u003c\/i\u003e\u003ci\u003e219\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.2 The RF Design Process 220\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.2.1 The Role of the RF Planner \u003c\/i\u003e\u003ci\u003e220\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.2.2 RF Measurements \u003c\/i\u003e\u003ci\u003e220\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.2.3 The Initial RF Measurements \u003c\/i\u003e\u003ci\u003e221\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.2.4 Measurements of Existing Coverage Level \u003c\/i\u003e\u003ci\u003e222\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.2.5 RF Survey Measurement \u003c\/i\u003e\u003ci\u003e223\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.2.6 Planning the Measurements \u003c\/i\u003e\u003ci\u003e224\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.2.7 Post Implementation Measurements \u003c\/i\u003e\u003ci\u003e226\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.2.8 Free Space Loss \u003c\/i\u003e\u003ci\u003e227\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.2.9 The One Meter Test \u003c\/i\u003e\u003ci\u003e227\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.3 Designing the Optimum Indoor Solution 229\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.3.1 Adapt the Design to Reality \u003c\/i\u003e\u003ci\u003e229\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.3.2 Learn from the Mistakes of Others \u003c\/i\u003e\u003ci\u003e229\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.3.3 Common Mistakes When Designing Indoor Solutions \u003c\/i\u003e\u003ci\u003e232\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.3.4 Planning the Antenna Locations \u003c\/i\u003e\u003ci\u003e233\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.3.5 The ‘Corridor Effect’ \u003c\/i\u003e\u003ci\u003e235\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.3.6 Fire Cells Inside the Building \u003c\/i\u003e\u003ci\u003e236\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.3.7 Indoor Antenna Performance \u003c\/i\u003e\u003ci\u003e236\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.3.8 The ‘Corner Office Problem’ \u003c\/i\u003e\u003ci\u003e243\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.3.9 Interleaving Antennas In\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003ebetween Floors \u003c\/i\u003e\u003ci\u003e244\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.3.10 Planning for Full Indoor Coverage \u003c\/i\u003e\u003ci\u003e247\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.3.11 The Cost of Indoor Design Levels \u003c\/i\u003e\u003ci\u003e249\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.4 Indoor Design Strategy 250\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.4.1 Hotspot Planning Inside Buildings \u003c\/i\u003e\u003ci\u003e250\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.4.2 Special Design Considerations \u003c\/i\u003e\u003ci\u003e255\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.4.3 The Design Flow \u003c\/i\u003e\u003ci\u003e256\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.4.4 Placing the Indoor Antennas \u003c\/i\u003e\u003ci\u003e256\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.5 Handover Considerations Inside Buildings 257\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.5.1 Indoor 2G Handover Planning \u003c\/i\u003e\u003ci\u003e258\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.5.2 Indoor 3G Handover Planning \u003c\/i\u003e\u003ci\u003e259\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.5.3 Handover Zone Size \u003c\/i\u003e\u003ci\u003e261\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.6 Elevator Coverage 262\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.6.1 Elevator Installation Challenges \u003c\/i\u003e\u003ci\u003e262\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.6.2 The Most Common Coverage Elevator Solution \u003c\/i\u003e\u003ci\u003e262\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.6.3 Antenna Inside the Shaft \u003c\/i\u003e\u003ci\u003e262\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.6.4 Repeater in the Lift\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003ecar \u003c\/i\u003e\u003ci\u003e264\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.6.5 DAS Antenna in the Lift\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003ecar \u003c\/i\u003e\u003ci\u003e264\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.6.6 Passive Repeaters in Elevators \u003c\/i\u003e\u003ci\u003e265\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.6.7 Real\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003elife Example of a Passive Repeater in an Elevator \u003c\/i\u003e\u003ci\u003e266\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.6.8 Control the Elevator HO Zone \u003c\/i\u003e\u003ci\u003e267\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.6.9 Elevator HO Zone Size \u003c\/i\u003e\u003ci\u003e267\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.6.10 Challenges with Elevator Repeaters for Large Shafts \u003c\/i\u003e\u003ci\u003e268\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.7 Multioperator Systems 276\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.7.1 Multioperator DAS Solutions Compatibility \u003c\/i\u003e\u003ci\u003e276\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.7.2 The Combiner System \u003c\/i\u003e\u003ci\u003e283\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.7.3 Inter\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003emodulation Distortion \u003c\/i\u003e\u003ci\u003e284\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.7.4 How to Minimize PIM \u003c\/i\u003e\u003ci\u003e285\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.7.5 IMD Products \u003c\/i\u003e\u003ci\u003e286\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.8 Co\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003eexistence Issues for 2G\/3G 287\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.8.1 Spurious Emissions \u003c\/i\u003e\u003ci\u003e287\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.8.2 Combined DAS for 2G-900 and 3G \u003c\/i\u003e\u003ci\u003e288\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.8.3 Combined DAS for 2G-1800 and 3G \u003c\/i\u003e\u003ci\u003e288\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.9 Co\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003eexistence Issues for 3G\/3G 289\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.9.1 Adjacent Channel Interference Power Ratio \u003c\/i\u003e\u003ci\u003e290\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.9.2 The ACIR Problem with Indoor DAS \u003c\/i\u003e\u003ci\u003e291\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.9.3 Solving the ACIR Problem Inside Buildings \u003c\/i\u003e\u003ci\u003e292\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.10 Multioperator Requirements 293\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.10.1 Multioperator Agreement \u003c\/i\u003e\u003ci\u003e294\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.10.2 Parties Involved in the Indoor Project \u003c\/i\u003e\u003ci\u003e294\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e5.10.3 The Most Important Aspects to Cover in the MOA \u003c\/i\u003e\u003ci\u003e294\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003cb\u003e\u003ci\u003e6 Traffic Dimensioning 297\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e6.1 Erlang, the Traffic Measurement 297\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e6.1.1 What is One Erlang? \u003c\/i\u003e\u003ci\u003e298\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e6.1.2 Call Blocking, Grade of Service \u003c\/i\u003e\u003ci\u003e299\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e6.1.3 The Erlang B Table \u003c\/i\u003e\u003ci\u003e299\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e6.1.4 User Types, User Traffic Profile \u003c\/i\u003e\u003ci\u003e301\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e6.1.5 Save on Cost, Use the Erlang Table \u003c\/i\u003e\u003ci\u003e302\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e6.1.6 When Not to Use Erlang \u003c\/i\u003e\u003ci\u003e302\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e6.1.7 2G Radio Channels and Erlang \u003c\/i\u003e\u003ci\u003e303\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e6.1.8 3G Channels and Erlang \u003c\/i\u003e\u003ci\u003e303\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e6.1.9 Trunking Gain, Resource Sharing \u003c\/i\u003e\u003ci\u003e304\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e6.1.10 Cell Configuration in Indoor Projects \u003c\/i\u003e\u003ci\u003e305\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e6.1.11 Busy Hour and Return on Investment Calculations \u003c\/i\u003e\u003ci\u003e307\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e6.1.12 Base Station Hotels \u003c\/i\u003e\u003ci\u003e313\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e6.2 Data Capacity 315\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e6.2.1 Application\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003edriven Data Load \u003c\/i\u003e\u003ci\u003e316\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e6.2.2 Data offload to Wi\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003eFi and Small Cells \u003c\/i\u003e\u003ci\u003e319\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e6.2.3 Future\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003eproof Your DAS to Handle More Data Load \u003c\/i\u003e\u003ci\u003e319\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e6.2.4 Event\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003edriven Data Load \u003c\/i\u003e\u003ci\u003e323\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e6.2.5 Calculating the Data Load \u003c\/i\u003e\u003ci\u003e323\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003cb\u003e\u003ci\u003e7 Noise 327\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e7.1 Noise Fundamentals 327\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e7.1.1 Thermal Noise \u003c\/i\u003e\u003ci\u003e328\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e7.1.2 Noise Factor \u003c\/i\u003e\u003ci\u003e329\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e7.1.3 Noise Figure \u003c\/i\u003e\u003ci\u003e329\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e7.1.4 Noise Floor \u003c\/i\u003e\u003ci\u003e329\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e7.1.5 The Receiver Sensitivity \u003c\/i\u003e\u003ci\u003e330\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e7.1.6 Noise Figure of Amplifiers \u003c\/i\u003e\u003ci\u003e331\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e7.1.7 Noise Factor of Coax Cables \u003c\/i\u003e\u003ci\u003e332\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e7.2 Cascaded Noise 334\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e7.2.1 The Friis Formula \u003c\/i\u003e\u003ci\u003e334\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e7.2.2 Amplifier After the Cable Loss \u003c\/i\u003e\u003ci\u003e335\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e7.2.3 Amplifier Prior to the Cable Loss \u003c\/i\u003e\u003ci\u003e337\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e7.2.4 Problems with Passive Cables and Passive DAS \u003c\/i\u003e\u003ci\u003e339\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e7.3 Noise Power 341\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e7.3.1 Calculating the Noise Power of a System \u003c\/i\u003e\u003ci\u003e342\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e7.4 Noise Power from Parallel Systems 346\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e7.4.1 Calculating Noise Power from Parallel Sources \u003c\/i\u003e\u003ci\u003e346\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e7.5 Noise Control 347\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e7.5.1 Noise Load on Base Stations \u003c\/i\u003e\u003ci\u003e347\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e7.5.2 Noise and 2G Base Stations \u003c\/i\u003e\u003ci\u003e348\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e7.5.3 Noise and 3G Base Stations \u003c\/i\u003e\u003ci\u003e348\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e7.6 Updating a Passive DAS from 2G to 3G\/4G 349\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e7.6.1 The 3G\/4G Challenge \u003c\/i\u003e\u003ci\u003e349\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e7.6.2 The 3G Problem \u003c\/i\u003e\u003ci\u003e350\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e7.6.3 Solution 1, In\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003eline BDA \u003c\/i\u003e\u003ci\u003e351\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e7.6.4 Solution 2: Active DAS Overlay \u003c\/i\u003e\u003ci\u003e355\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e7.6.5 Conclusions on Noise and Noise Control \u003c\/i\u003e\u003ci\u003e359\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003cb\u003e\u003ci\u003e8 The Link Budget 361\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e8.1 The Components and Calculations of the RF Link 362\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e8.1.1 The Maximum Allowable Path Loss \u003c\/i\u003e\u003ci\u003e362\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e8.1.2 The Components in the Link Budget \u003c\/i\u003e\u003ci\u003e362\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e8.1.3 Link Budgets for Indoor Systems \u003c\/i\u003e\u003ci\u003e374\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e8.1.4 Passive DAS Link Budget \u003c\/i\u003e\u003ci\u003e376\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e8.1.5 Active DAS Link Budget \u003c\/i\u003e\u003ci\u003e376\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e8.1.6 The Free Space Loss \u003c\/i\u003e\u003ci\u003e377\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e8.1.7 The Modified Indoor Model \u003c\/i\u003e\u003ci\u003e377\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e8.1.8 The PLS Model \u003c\/i\u003e\u003ci\u003e379\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e8.1.9 Calculating the Antenna Service Radius \u003c\/i\u003e\u003ci\u003e380\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e8.2 4G Link Budget 382\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e8.2.1 4G Design Levels \u003c\/i\u003e\u003ci\u003e383\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e8.2.2 RSRP, Reference Symbol Transmit Power \u003c\/i\u003e\u003ci\u003e384\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e8.2.3 4G RSSI Signal Power \u003c\/i\u003e\u003ci\u003e385\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e8.2.4 4G Coverage vs. Capacity \u003c\/i\u003e\u003ci\u003e385\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e8.2.5 4G DL RS Link Budget Example \u003c\/i\u003e\u003ci\u003e386\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003cb\u003e\u003ci\u003e9 Tools for Indoor Radio Planning 389\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.1 Live and Learn 389\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.2 Diagram Tools 390\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.2.1 Simple or Advanced? \u003c\/i\u003e\u003ci\u003e390\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.3 Radio Survey Tools 391\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.3.1 Use Only Calibrated Equipment \u003c\/i\u003e\u003ci\u003e391\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.4 The Simple Tools and Tips 391\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.4.1 Use a Digital Camera \u003c\/i\u003e\u003ci\u003e391\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.4.2 Use the World Wide Web \u003c\/i\u003e\u003ci\u003e392\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.4.3 Traffic Calculations \u003c\/i\u003e\u003ci\u003e392\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.5 Tools for Link Budget Calculations 392\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.6 Tools for Indoor Predictions 392\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.6.1 Spreadsheets Can Do Most of the Job \u003c\/i\u003e\u003ci\u003e394\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.6.2 The More Advanced RF Prediction Models \u003c\/i\u003e\u003ci\u003e394\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.7 The Advanced Toolkit (iBwave Unity, Design, and Mobile from iBwave.com) 395\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.7.1 Save Time, Keep Costs and Mistakes to a Minimum \u003c\/i\u003e\u003ci\u003e396\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.7.2 Collaboration, Visibility, and Revision Controls \u003c\/i\u003e\u003ci\u003e396\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.7.3 Multisystem or Multioperator Small Cells, DAS, and Wi\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003eFi \u003c\/i\u003e\u003ci\u003e397\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.7.4 The Site Survey Tool \u003c\/i\u003e\u003ci\u003e397\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.7.5 The Mobile Planning Tool \u003c\/i\u003e\u003ci\u003e397\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.7.6 Import Floor Plans \u003c\/i\u003e\u003ci\u003e397\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.7.7 Schematic Diagram \u003c\/i\u003e\u003ci\u003e398\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.7.8 Floor Plan Diagram \u003c\/i\u003e\u003ci\u003e401\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.7.9 Site Documentation \u003c\/i\u003e\u003ci\u003e401\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.7.10 Error Detection \u003c\/i\u003e\u003ci\u003e401\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.7.11 Component Database \u003c\/i\u003e\u003ci\u003e402\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.7.12 RF Propagation \u003c\/i\u003e\u003ci\u003e403\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.7.13 RF Optimization \u003c\/i\u003e\u003ci\u003e403\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.7.14 Complex Environments \u003c\/i\u003e\u003ci\u003e404\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.7.15 Importing an RF Survey \u003c\/i\u003e\u003ci\u003e404\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.7.16 Equipment List and Project Cost Report \u003c\/i\u003e\u003ci\u003e405\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.7.17 RF and Installation Report \u003c\/i\u003e\u003ci\u003e405\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.7.18 Fully Integrated \u003c\/i\u003e\u003ci\u003e406\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.7.19 Outputs from the Tool \u003c\/i\u003e\u003ci\u003e406\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.7.20 Team Collaboration \u003c\/i\u003e\u003ci\u003e407\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.7.21 Make Sure to Learn the Basics \u003c\/i\u003e\u003ci\u003e408\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.8 Tools for DAS Verification 408\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.8.1 3G Example Measurement \u003c\/i\u003e\u003ci\u003e409\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.8.2 4G Example Measurement \u003c\/i\u003e\u003ci\u003e412\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e9.8.3 Final Word on Tools \u003c\/i\u003e\u003ci\u003e412\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003cb\u003e\u003ci\u003e10 Optimizing the Radio Resource Management Parameters on Node B When Interfacing to an Active DAS, BDA, LNA or TMA 413\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e10.1 Introduction 413\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e10.1.1 3G Radio Performance is All About Noise and Power Control \u003c\/i\u003e\u003ci\u003e413\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e10.1.2 3G RF Parameter Reference is Different from 2G \u003c\/i\u003e\u003ci\u003e414\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e10.1.3 Adjust the Parameters \u003c\/i\u003e\u003ci\u003e414\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e10.1.4 How to Adjust this in the RAN \u003c\/i\u003e\u003ci\u003e415\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e10.1.5 Switch Off the LNA in Node B when Using Active DAS \u003c\/i\u003e\u003ci\u003e415\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e10.2 Impact of DL Power Offset 415\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e10.2.1 Access Burst \u003c\/i\u003e\u003ci\u003e415\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e10.2.2 Power Offset Between Node B and the Active DAS \u003c\/i\u003e\u003ci\u003e416\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e10.2.3 Solution \u003c\/i\u003e\u003ci\u003e417\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e10.2.4 Impact on the UL of Node B \u003c\/i\u003e\u003ci\u003e417\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e10.2.5 Admission Control \u003c\/i\u003e\u003ci\u003e417\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e10.3 Impact of Noise Power 417\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e10.3.1 The UL Noise Increase on Node B \u003c\/i\u003e\u003ci\u003e418\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e10.4 Delay of the Active DAS 418\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e10.4.1 Solution \u003c\/i\u003e\u003ci\u003e419\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e10.5 Impact of External Noise Power 419\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e10.5.1 To Calculate the Noise Power \u003c\/i\u003e\u003ci\u003e419\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e10.5.2 To Calculate the UL Attenuator \u003c\/i\u003e\u003ci\u003e419\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e10.5.3 Affect on Admission Control \u003c\/i\u003e\u003ci\u003e421\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003cb\u003e\u003ci\u003e11 Tunnel Radio Planning 423\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.1 The Typical Tunnel Solution 424\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.1.1 The Penetration Loss into the Train Coach \u003c\/i\u003e\u003ci\u003e425\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.2 The Tunnel HO Zone 426\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.2.1 Establishing the HO Zone Size \u003c\/i\u003e\u003ci\u003e427\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.2.2 The Link Loss and the Effect on the Handover Zone Design \u003c\/i\u003e\u003ci\u003e428\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.2.3 The Handover Challenge Between the Tunnel and Outside Network \u003c\/i\u003e\u003ci\u003e429\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.2.4 Possible Solutions for the Tunnel HO Problem to the Outside Network \u003c\/i\u003e\u003ci\u003e430\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.3 Covering Tunnels with Antennas 432\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.4 Radiating Cable Solutions 434\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.4.1 The Radiating Cable \u003c\/i\u003e\u003ci\u003e435\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.4.2 Calculating the Coverage Level \u003c\/i\u003e\u003ci\u003e437\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.4.3 Installation Challenges Using Radiating Cable \u003c\/i\u003e\u003ci\u003e442\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.5 Tunnel Solutions, Cascaded BDAs 444\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.5.1 Cascaded Noise Build\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003eup \u003c\/i\u003e\u003ci\u003e444\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.5.2 Example of a Real\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003elife Cascaded BDA System \u003c\/i\u003e\u003ci\u003e445\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.6 Tunnel Solutions, T\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003eSystems 446\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.6.1 T\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003esystems, Principle \u003c\/i\u003e\u003ci\u003e447\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.6.2 Example of a Real\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003elife T\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003esystem with BDAs \u003c\/i\u003e\u003ci\u003e447\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.6.3 T\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003esystems with Antenna Distribution \u003c\/i\u003e\u003ci\u003e449\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.7 Handover Design inside Tunnels 450\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.7.1 General Considerations \u003c\/i\u003e\u003ci\u003e450\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.7.2 Using Antennas for the HO Zone in Tunnels \u003c\/i\u003e\u003ci\u003e451\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.7.3 Using Parallel Radiating Cable for the HO Zone \u003c\/i\u003e\u003ci\u003e453\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.7.4 Using a Coupler for the HO Zone \u003c\/i\u003e\u003ci\u003e454\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.7.5 Avoid Common HO Zone Mistakes \u003c\/i\u003e\u003ci\u003e455\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.8 Redundancy in Tunnel Coverage Solutions 455\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.8.1 Multiple Cell Redundancy in Tunnels \u003c\/i\u003e\u003ci\u003e457\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.9 Sector Strategy for Larger Metro Tunnel Projects 458\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.9.1 Common Cell Plans for Large Metro Rail Systems \u003c\/i\u003e\u003ci\u003e458\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.9.2 Using Distributed Base Station in a Metro Tunnel Solution \u003c\/i\u003e\u003ci\u003e461\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.9.3 Using Optical Fibre DAS in a Metro Tunnel Solution \u003c\/i\u003e\u003ci\u003e461\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.10 RF Test Specification of Tunnel Projects 463\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.11 Timing Issues in DAS for Tunnels 464\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.11.1 Calculating the Total Delay of a Tunnel Solution \u003c\/i\u003e\u003ci\u003e466\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.11.2 Solving the Delay Problem in the Tunnel DAS \u003c\/i\u003e\u003ci\u003e468\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.11.3 High Speed Rail Tunnels \u003c\/i\u003e\u003ci\u003e468\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e11.11.4 Road Tunnels \u003c\/i\u003e\u003ci\u003e469\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003cb\u003e\u003ci\u003e12 Covering Indoor Users From the Outdoor Network 471\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e12.1 The Challenges of Reaching Indoor Users From the Macro Network 471\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e12.1.1 Micro Cell (Small Cell) Deployment for IB Coverage \u003c\/i\u003e\u003ci\u003e472\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e12.1.2 Antenna Locations for Micro Cells \u003c\/i\u003e\u003ci\u003e474\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e12.1.3 Antenna Clearance for Micro Cells \u003c\/i\u003e\u003ci\u003e475\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e12.1.4 The Canyon Effect \u003c\/i\u003e\u003ci\u003e476\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e12.2 Micro Cell Capacity 476\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e12.3 ODAS – Outdoor Distributed Antenna Systems 478\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e12.3.1 The Base Station Hotel and Remote Units \u003c\/i\u003e\u003ci\u003e479\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e12.3.2 Simulcast and Flexible Capacity \u003c\/i\u003e\u003ci\u003e480\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e12.3.3 Different Sector Plans for Different Services \u003c\/i\u003e\u003ci\u003e481\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e12.4 Digital Distribution on DAS 481\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e12.4.1 Advantages of ODDAS \u003c\/i\u003e\u003ci\u003e482\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e12.4.2 Remote Radio Heads \u003c\/i\u003e\u003ci\u003e483\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e12.4.3 Integrating the ODAS with the Macro Network \u003c\/i\u003e\u003ci\u003e484\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e12.5 High Speed Rail Solutions 487\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e12.5.1 Calculating the Required Handover Zone Size for High Speed Rail \u003c\/i\u003e\u003ci\u003e487\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e12.5.2 Distributed Base Stations for High Speed Rail \u003c\/i\u003e\u003ci\u003e488\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e12.5.3 Covering High Speed Rail with Outdoor Distributed Antenna Systems \u003c\/i\u003e\u003ci\u003e490\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e12.5.4 Optimize the Location of the ODAS and Base Station Antennas for High Speed Rail \u003c\/i\u003e\u003ci\u003e491\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e12.5.5 The Doppler Effect \u003c\/i\u003e\u003ci\u003e492\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003cb\u003e\u003ci\u003e13 Small Cells Indoors 495\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e13.1 Femtocells 497\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e13.1.1 Types of Femtocells \u003c\/i\u003e\u003ci\u003e499\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e13.1.2 The Pico\/Femtocell Principle \u003c\/i\u003e\u003ci\u003e499\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e13.1.3 Typical Pico Cell Design \u003c\/i\u003e\u003ci\u003e501\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e13.1.4 Extending Pico Cell Coverage with Active DAS \u003c\/i\u003e\u003ci\u003e503\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e13.1.5 Combining Pico Cells into the Same DAS (only 2G) \u003c\/i\u003e\u003ci\u003e505\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e13.1.6 Cost Savings When Combining Capacity of 2G Pico Cells \u003c\/i\u003e\u003ci\u003e505\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e13.2 Heterogeneous Networks (HetNets) 507\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e13.3 Implementing Small Cells Indoors 507\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e13.3.1 Planning Considerations with Indoor Small Cells \u003c\/i\u003e\u003ci\u003e510\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e13.4 Planning Examples with Femtocells 511\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e13.4.1 Small Office Space \u003c\/i\u003e\u003ci\u003e512\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e13.4.2 Medium\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003esized Office Space \u003c\/i\u003e\u003ci\u003e513\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e13.4.3 Large Office\/Meeting Space \u003c\/i\u003e\u003ci\u003e513\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e13.4.4 Final Word on Small Cells \u003c\/i\u003e\u003ci\u003e516\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003cb\u003e\u003ci\u003e14 Application Examples 517\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e14.1 Office Building Design 517\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e14.1.1 Typical Features and Checklist for Office Buildings \u003c\/i\u003e\u003ci\u003e518\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e14.1.2 Small to Medium\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003eSized Office Building \u003c\/i\u003e\u003ci\u003e518\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e14.1.3 Large Office Buildings \u003c\/i\u003e\u003ci\u003e520\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e14.1.4 High\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003erises with Open Vertical Cavities \u003c\/i\u003e\u003ci\u003e521\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e14.2 Malls, Warehouses, and Large Structure Design 522\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e14.2.1 Typical Features and Checklist for Malls, Warehouses and Large Structures \u003c\/i\u003e\u003ci\u003e524\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e14.2.2 The Different Areas of Shopping Malls \u003c\/i\u003e\u003ci\u003e524\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e14.3 Warehouses and Convention Centers 526\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e14.3.1 Typical Features and Checklist for Warehouses and Convention Center DAS Deployments \u003c\/i\u003e\u003ci\u003e528\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e14.4 Campus Area Design 529\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e14.4.1 Typical Features and Checklist for Campus DAS Deployments \u003c\/i\u003e\u003ci\u003e529\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e14.4.2 Base Station Hotels Are Ideal for Campus DAS \u003c\/i\u003e\u003ci\u003e529\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e14.5 Airport Design 530\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e14.5.1 Typical Features and Checklist for Airports \u003c\/i\u003e\u003ci\u003e530\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e14.5.2 The Different Areas in the Airport \u003c\/i\u003e\u003ci\u003e531\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e14.6 Sports Arena Design 534\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e14.6.1 Typical Features and Checklist for Stadiums and Arenas \u003c\/i\u003e\u003ci\u003e535\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e14.6.2 Arenas Require 3D Coverage and Capacity Planning \u003c\/i\u003e\u003ci\u003e535\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e14.6.3 Capacity Considerations in the Arena \u003c\/i\u003e\u003ci\u003e535\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e14.6.4 RF Design Considerations in the Sports Arena \u003c\/i\u003e\u003ci\u003e540\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e14.6.5 Antenna Locations in the Sports Arena \u003c\/i\u003e\u003ci\u003e542\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e14.6.6 Interference Across the Sports Arena \u003c\/i\u003e\u003ci\u003e547\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e14.6.7 Upgrading Old 2G designs, with 3G and 4G Overlay on a Sports Arena \u003c\/i\u003e\u003ci\u003e549\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e14.6.8 The HO Zone Challenge in the Arena \u003c\/i\u003e\u003ci\u003e550\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e14.6.9 The Ideal DAS Design for a Stadium \u003c\/i\u003e\u003ci\u003e553\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e14.7 Final Remark on Application Examples 554\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003cb\u003e\u003ci\u003e15 Planning Procedure, Installation, Commissioning, and Documentation 555\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e15.1 The Design Phase 556\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e15.1.1 Design Inputs \u003c\/i\u003e\u003ci\u003e556\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e15.1.2 Draft Design Process \u003c\/i\u003e\u003ci\u003e558\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e15.1.3 Site Visit – Survey \u003c\/i\u003e\u003ci\u003e558\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e15.1.4 Update of Draft Design \u003c\/i\u003e\u003ci\u003e560\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e15.2 The Implementation Phase 560\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e15.2.1 Installation \u003c\/i\u003e\u003ci\u003e560\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e15.2.2 Post\u003c\/i\u003e\u003ci\u003e‐\u003c\/i\u003e\u003ci\u003einstallation Verification \u003c\/i\u003e\u003ci\u003e561\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e15.2.3 DAS Test \u003c\/i\u003e\u003ci\u003e561\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e15.2.4 Commissioning \u003c\/i\u003e\u003ci\u003e562\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e15.3 The Verification Phase 564\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e15.3.1 RF Verification \u003c\/i\u003e\u003ci\u003e564\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e15.3.2 Live Traffic Test \u003c\/i\u003e\u003ci\u003e564\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003e15.4 Conclusion 565\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003cb\u003e\u003ci\u003eReferences 567\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003e\u003cb\u003e\u003ci\u003eAppendix 569\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003e\u003ci\u003eReference Material 569\u003c\/i\u003e\u003c\/p\u003e \u003cp\u003e\u003cb\u003e\u003ci\u003eIndex 581\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eMorten Tolstrup\u003c\/strong\u003e has held a number of jobs for major DAS suppliers over the past decade, in multiple flagship DAS projects and deployments on a global scale. In addition to this, he spent 13 years in a number of different engineering positions with a mobile operator in Denmark, mainly focusing on indoor RF planning, tunnels, airports andSmall Cells. Morten has presented more than 100 papers, conference workshops and DAS training events around the world. This book is now the official textbook for a DAS planning Certification training program from a leading DAS supplier.\u003c\/p\u003e","brand":"Wiley","offers":[{"title":"Default Title","offer_id":47989415870693,"sku":"NP9781118913628","price":152.95,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1842\/7735\/files\/9781118913628.jpg?v=1761784016","url":"https:\/\/k12savings.com\/es\/products\/indoor-radio-planning-isbn-9781118913628","provider":"K12savings","version":"1.0","type":"link"}